Funkcja
- Can be installed without shutting off the power
- Excellent AT performance.The maximum inductive at the operating point of AT sheath can reach 25kV
- Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops
- Large span lengths and the largest span is over 1000m
- Good performance of tensile strength and temperature
- The design life span is over 30 years
- Self-supporting aerial,especially applicable for installation on the same pole as 220V and below power transmission lines

Podstawowe specyfikacje
Technical Parameters(Ref)
| Ref. Outer diameter (mm) | Ref. weigh(kg/km) | Rec.daily max working Tensile(KN) | Max allowable working tensile (KN) | Break strength | Strength member CSA (mm2) | Modulus of elasticity(KN/mm2) | Heat expansion coefficient(x10-6/K) | Suitable span(m) (NESC Standard,m) | ||||
| PE sheath | AT sheath | A | B | C | D | |||||||
| 11.8 | 117 | 124 | 15 | 4 | 10 | 4.6 | 7.6 | 1.8 | 160 | 100 | 140 | 100 |
| 12 | 121 | 129 | 2.25 | 6 | 15 | 7.6 | 8.3 | 1.5 | 230 | 150 | 200 | 150 |
| 12.3 | 126 | 134 | 3 | 8 | 20 | 10.35 | 9.45 | 13 | 300 | 200 | 290 | 200 |
| 12.6 | 133 | 141 | 3.6 | 10 | 24 | 13.8 | 10.8 | 1.2 | 370 | 250 | 350 | 250 |
| 12.8 | 138 | 145 | 4.5 | 12 | 30 | 14.3 | 11.8 | 1 | 420 | 280 | 400 | 280 |
| 13.1 | 145 | 153 | 5.4 | 15 | 36 | 18.4 | 13.6 | 0.9 | 480 | 320 | 460 | 320 |
| 13.5 | 155 | 163 | 6.75 | 18 | 45 | 220 | 16.4 | 0.6 | 570 | 380 | 550 | 380 |
| 13.8 | 163 | 171 | 7.95 | 22 | 53 | 26.4 | 18 | 0.3 | 670 | 460 | 650 | 460 |
| 14.4 | 177 | 186 | 9 | 26 | 60 | 32.2 | 19.1 | 0.1 | 750 | 530 | 750 | 510 |
| 14.6 | 182 | 191 | 10.5 | 28 | 70 | 33 | 19.6 | 0.1 | 800 | 560 | 800 | 560 |
| 14.8 | 195 | 204 | 12.75 | 34 | 85 | 40 | 20.1 | 0.1 | 880 | 650 | 880 | 650 |
Optical Characteristics
| fiber type | Attenuation | (OFL) | Numerical Aperture | Cable Cut-off Wavelength(λcc) | |||
| Condition | 1310/1550nm | 850/1300nm | 850/1300nm | ||||
| Typical | Max | Typical | Max | ||||
| unit | dB/km | dB/km | dB/km | dB/km | MHz.km | — | nm |
| G652 | 0.35/0.21 | 0.4/0.3 | — | — | — | — | ≤1260 |
| G655 | 0.36/0.22 | 0.4/0.3 | — | — | — | — | ≤1450 |
| 50/125 | — | — | 3.0/1.0 | 3.5/1.5 | ≥500/500 | 0.200±0.015 | — |
| 62.5/125 | — | — | 3.0/1.0 | 3.5/1.5 | ≥200/500 | 0.275±0.015 | — |
Transport/Storage/Operating Temperature:-40℃~+70℃
Często zadawane pytania
Tak. Jesteśmy prawdziwym producentem zatrudniającym ponad 500 pracowników.
Od 2001 roku.
Tak, dostępne jest małe zamówienie. Wspieramy nowe projekty naszych klientów, ponieważ wiemy, że biznes zawsze opiera się na małych zamówieniach.
10 lat na kabel LAN, 25 lat na kabel światłowodowy
ISO9001, SGS, UL, CPR, CE, RoHs
Zwykle w ciągu 10-15 dni roboczych
Kabel Lan, nasza roczna produkcja wynosi 500000 * 305 m
Zewnętrzny/wewnętrzny kabel światłowodowy, nasza roczna produkcja wynosi 8 000 000 KM;
Kabel FTTH/FTTX/FTTA, to 6 000 000 km rocznie;
Patchcord/pigtaile, to 12 400 000 sztuk rocznie.
T/T, L/C, Western Union i Ali płacą.
Tak. Dostarczamy usługi OEM i ODM. Możesz przesłać nam swój rysunek lub wykonamy projekt przez nasz profesjonalny, dostosowany do indywidualnych potrzeb zespół.