1kV for Fixed installations such as distribution networks or industrial installations.
Product Attributes:
Model:
  • 5 Core Xlpe 16mm2 Low Voltage Power Cable Low Smoke Halogen Free
Model Name:WDZ-YJYConductor Type::Class 2
Size::1.5~630mm²Nos.of Core::2~5
Sheath::LSZH (LOW SMOKE AND HELOGEN FREE)Insulation ::XLPE
Fire Performance::IEC 60332-1Temperature Rating::-25C Up To +90℃
High Light:

16mm2 Low Voltage Power Cable

,

5core Low Voltage Power Cable

 

▼wdz-yjy 5 core xlpe cable 16mm2 Low Smoke Halogen Free Cable

 

Application:

1kV for Fixed installations such as distribution networks or industrial installations.

Constraction:

Core Conductor :annealed copper (stranded core)
Popular sizes: 2~5 core x1.5~630mm²
Insulation: XLPE
Jacket: LSZH
Voltage suitable: 0.6/1kV
Fire performance: IEC 60332-1
Approval:QS in China

Advantage:

Flame retardancyIn actual use, wires and cables are laid horizontally and vertically. For open wire laying and channel laying methods, our company’s low-smoke and halogen-free cables pass the bundle burning test for bundled applications, and for single-layed low-smoke halogen-free cables, they pass the single vertical burning test.
Smoke densityThe smoke of burning gas is an important indicator of the burning performance of wires and cables, and it is also an important factor affecting fire rescue and self-rescue under actual fire conditions. The light transmittance of our company’s low-smoke halogen-free cables is not less than 60%.
CorrosiveThe combustion of ordinary polyvinyl chloride cables produces a large amount of HCL gas. The products not only cause serious harm to the human body, but also severely corrode various fire-fighting and other facilities. After testing, the weighted value of pH should not be less than 4.3, and the weighted value of conductivity should not exceed 10μS/mm

Technical parameters:
2 Core&3 Core

Cross section of conductor(mm²)Conductor structureInsulation Thickness(mm)Copper sheath thickness(mm)Approx.cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
2×610.71.811.63.08
2×1070.71.813.81.83
2×1670.71.815.71.15
2×2570.91.818.90.727
2×3570.91.820.90.524
2×50101.01.824.60.387
2×70141.11.928.20.268
2×95191.12.032.40.193
2×120241.22.235.80.153
2×150301.42.339.60.124
2×185371.62.544.00.0991
2×240481.72.649.40.0754
2×300611.82.854.30.0601
3×610.71.812.23.08
3×1070.71.814.61.83
3×1670.71.816.71.15
3×2570.91.820.10.727
3×3570.91.822.30.524
3×50101.01.926.20.387
3×70141.12.030.30.268
3×95191.12.238.00.193
3×120241.22.334.60.153
3×150301.42.438.50.124
3×185371.62.647.30.0991
3×240481.72.853.10.0754
3×300611.82.958.20.0601

Service
1. Customer is God. We will cherish every client, every cooperation by heart.
2. Free pre-sales service. We will provide the best proposal for each client.
3. Good sales service. We will provide free relative product operation, maintenance tips, and installation commissioning
technical advisory service when establishing cooperation relationships with clients.
4. Product warranty period is 2 years.
5. We guarantee to solve your problems within 24 hours in Shenzhen, 72 hours for other districts.
6. 24 hours hot-line telephone service. We will appoint a professional person to answer your question timely.

Related Product

Each cable consists of 8 colour coded 24AWG polyethylene insulated conductors. These are twisted together to form 4 pairs with varying lay lengths. These pairs are wrapped in an aluminium foil tape screen with a solid drain wire and jacketed in a heat resistant PVC rated material. The printing detail on the sheath, includes the cables part number, specification details and sequential metre markin
The bers, 250μm, are positioned in a loose tube made of a high modulus plastic. The tubes are lled with a water-resistant lling compound. The tube is wrapped with a layer of PSP longitudinally. Between the PSP and the loose tube water-blocking material is applied to keep the cable compact and watertight. Two parallel steel wires are placed at the two sides of the steel tape. The parallel steel wires are placed at the two sides tape. The cable is completed with a polyethylene (PE) sheath.
Optical fiber are housed in loose tubes that are made of high-modulus plastic and filled with tube filling compound. The tubes (and fillers) are stranded around a non-metallic central strength member and surrounded with dry water-blocking material to form a cable core.

If you have any interest in our Industry Solutions

please feel free to contact us & We are ready to serve you
taip

* Kami menghormati privasi anda. Apabila anda menyerahkan maklumat hubungan anda, kami bersetuju untuk hanya menghubungi anda mengikut peraturan kami Dasar Privasi.

Hubungi Sekarang

taip
Bagaimana anda ingin dihubungi?
* Kami menghormati privasi anda. Apabila anda menyerahkan maklumat hubungan anda, kami bersetuju untuk hanya menghubungi anda mengikut peraturan kami Dasar Privasi.