• Trang chủ
  • Hợp tác điều hành
  • Liên hệ với chúng tôi
.play_icon_video{display:none;}
5 Core Xlpe 16mm2 Low Voltage Power Cable Low Smoke Halogen Free

5 Core Xlpe 16mm2 Low Voltage Power Cable Low Smoke Halogen Free

1kV for Fixed installations such as distribution networks or industrial installations.
Product Attributes:
Model:
  • 5 Core Xlpe 16mm2 Low Voltage Power Cable Low Smoke Halogen Free
Model Name:WDZ-YJYConductor Type::Class 2
Size::1.5~630mm²Nos.of Core::2~5
Sheath::LSZH (LOW SMOKE AND HELOGEN FREE)Insulation ::XLPE
Fire Performance::IEC 60332-1Temperature Rating::-25C Up To +90℃
High Light:

16mm2 Low Voltage Power Cable

,

5core Low Voltage Power Cable

 

▼wdz-yjy 5 core xlpe cable 16mm2 Low Smoke Halogen Free Cable

 

ứng dụng:

1kV for Fixed installations such as distribution networks or industrial installations.

Constraction:

Core Conductor :annealed copper (stranded core)
Popular sizes: 2~5 core x1.5~630mm²
Insulation: XLPE
Jacket: LSZH
Voltage suitable: 0.6/1kV
Fire performance: IEC 60332-1
Approval:QS in China

Advantage:

Flame retardancyIn actual use, wires and cables are laid horizontally and vertically. For open wire laying and channel laying methods, our company’s low-smoke and halogen-free cables pass the bundle burning test for bundled applications, and for single-layed low-smoke halogen-free cables, they pass the single vertical burning test.
Smoke densityThe smoke of burning gas is an important indicator of the burning performance of wires and cables, and it is also an important factor affecting fire rescue and self-rescue under actual fire conditions. The light transmittance of our company’s low-smoke halogen-free cables is not less than 60%.
CorrosiveThe combustion of ordinary polyvinyl chloride cables produces a large amount of HCL gas. The products not only cause serious harm to the human body, but also severely corrode various fire-fighting and other facilities. After testing, the weighted value of pH should not be less than 4.3, and the weighted value of conductivity should not exceed 10μS/mm

Technical parameters:
2 Core&3 Core

Cross section of conductor(mm²)Conductor structureInsulation Thickness(mm)Copper sheath thickness(mm)Approx.cable diameter(mm)Max resistance of conductor at 20℃ (Ω/km)
2×610.71.811.63.08
2×1070.71.813.81.83
2×1670.71.815.71.15
2×2570.91.818.90.727
2×3570.91.820.90.524
2×50101.01.824.60.387
2×70141.11.928.20.268
2×95191.12.032.40.193
2×120241.22.235.80.153
2×150301.42.339.60.124
2×185371.62.544.00.0991
2×240481.72.649.40.0754
2×300611.82.854.30.0601
3×610.71.812.23.08
3×1070.71.814.61.83
3×1670.71.816.71.15
3×2570.91.820.10.727
3×3570.91.822.30.524
3×50101.01.926.20.387
3×70141.12.030.30.268
3×95191.12.238.00.193
3×120241.22.334.60.153
3×150301.42.438.50.124
3×185371.62.647.30.0991
3×240481.72.853.10.0754
3×300611.82.958.20.0601

Service
1. Customer is God. We will cherish every client, every cooperation by heart.
2. Free pre-sales service. We will provide the best proposal for each client.
3. Good sales service. We will provide free relative product operation, maintenance tips, and installation commissioning
technical advisory service when establishing cooperation relationships with clients.
4. Product warranty period is 2 years.
5. We guarantee to solve your problems within 24 hours in Shenzhen, 72 hours for other districts.
6. 24 hours hot-line telephone service. We will appoint a professional person to answer your question timely.

Related Product

GYTC8A Figure-8 Cable with Aluminum Tape In the GYTC8A cable, single-mode/multimode fibers are positioned in the loose tubes, while the loose tubes strand together around metallic central strength member into a compact and circular cable core, and the water-blocking materials are distributed into interstices of it. After a APL is applied around the cable core, this part of cable accompanied with the stranded wires as the supporting part are completed with a PE sheath to be a figure-8 structure.
optical splice closures are used to distribute, splice, andstore the outdoor optical cables which enter and exit fromthe ends of the closure. There are two connection ways:direct connection and splitting connection. They areapplicable to situations such as overhead, man-well ofpipeline, embedded situation etc. Comparing with terminalbox, the closure requires much stricter requirement of seal. Features
Fiber optic adapters (also known as bulkheads) are used to join two fiber optic patch cables together. They are available for use with either singlemode or multimode patch cables. Wirenet provides an extensive line of fiber optic adapters that offer superior low loss performance with very high repeatability.

If you have any interest in our Industry Solutions

please feel free to contact us & We are ready to serve you
loại

* Chúng tôi tôn trọng sự riêng tư của bạn. Khi bạn gửi thông tin liên hệ của mình, chúng tôi đồng ý chỉ liên hệ với bạn theo quy định của chúng tôi. Chính sách bảo mật.

Liên hệ ngay

loại
Bạn muốn được liên lạc bằng cách nào?
* Chúng tôi tôn trọng sự riêng tư của bạn. Khi bạn gửi thông tin liên hệ của mình, chúng tôi đồng ý chỉ liên hệ với bạn theo quy định của chúng tôi. Chính sách bảo mật.